Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

The injury potential of Fogarty balloon catheters.

Authors: G, Byrnes; W A, Mac Gowan;

The injury potential of Fogarty balloon catheters.

Abstract

The problem of arterial injury following embolectomy using a balloon catheter is reviewed. Three illustrative clinical cases are presented. The cause of the arterial injury in these cases was due to rupture of the vessel. The hypotheses were that either the vessel was ruptured by direct penetration or bursting by overdistension of the balloon. The linear appearances of the arterial tear in two patients and a false aneurysm in the third suggested that bursting was the correct explanation. Laboratory investigation was carried out on animals and human cadavers and these confirmed that arterial injury and bursting can be caused by over-distension of the balloon catheter. If the maker's recommendations are strictly adhered to; that is, the balloon should not be over-inflated and the correct volume of fluid used then rupture of the artery is unlikely by occur.

Keywords

Male, Leg, Embolism, Arterial Occlusive Diseases, Thrombosis, Arteries, Middle Aged, Surgical Instruments, Catheterization, Dogs, Evaluation Studies as Topic, Animals, Humans, Female, Stress, Mechanical, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    28
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
28
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!