Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

[Medical compression therapy].

Authors: H M, Häfner; M, Eichner; M, Jünger;

[Medical compression therapy].

Abstract

In order to evaluate the correlation between the pressure exerted by compression stockings and a resulting improvement in venous hemodynamics, we carried out an open, randomized, prospective study on 22 patients (11 women and 11 men with an average age of 55.1 [10.3]) with chronic venous insufficiency (CVI) in the clinical stages C1-4, Ep, AS, Ap, PR. Dynamic strain gauge plethysmography was used to measure the acute effect on venous hemodynamics of 9 different compression stockings in compression class 2 (A-D). At the same time when venous function parameters were monitored, we also measured the pressure exerted by the compression stockings during rest and exercise. With all compression stockings the average resting pressure fulfilled in reclined patients the specifications for compression class 2 (25-35 mmHg at the ankle, CEN). The compression stockings lengthened venous refill time t0 in a statistically significant degree. The improvement in venous function was correlated with the ratios of maximal working pressure to resting pressure while standing (r = 0.97, p < 0.001). Compression stockings belonging to the same compression class vary in their acute effect on venous hemodynamics. The efficiency of the different therapeutic compression stockings was largely dependent on the amount of fabric stretch, which can be characterized in vivo with the ratio of maximum exerted pressure during movement to that while standing still. A knowledge of the hemodynamic effectivity of the various compression stockings allows the optimal stocking selection for each patient and his individual clinical situation.

Related Organizations
Keywords

Adult, Male, Middle Aged, Bandages, Plethysmography, Varicose Veins, Treatment Outcome, Venous Insufficiency, Humans, Female, Prospective Studies, Venous Pressure, Aged

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    9
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
9
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!