Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Archivio istituziona...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
addClaim

Randomisierte multizenter-vergleichsstudie von elastischen strÃ1⁄4mpfen versus bandagen nach varizenchirurgie

Authors: Mariani, Fabrizio; Marone, E. M.; Gasbarro, V.; Bucalossi, M.; Spelta, S.; Amsler, F.; Agnati, M.; +1 Authors

Randomisierte multizenter-vergleichsstudie von elastischen strÃ1⁄4mpfen versus bandagen nach varizenchirurgie

Abstract

Traditionally, venous leg ulcers are treated with firm nonelastic bandages. Medical compression stockings are not the first choice although comparative studies found them equally effective or superior to bandages. Patients, methods: We report on a multi-center randomized trial with 60 patients treated with either short stretch multi-layer bandages or a two-stocking system (Sigvaris® Ulcer X® kit). Three patients have been excluded because their ankle movement was restricted to the extent that they could not put on the stockings and 1 patient withdrew consent. Patient characteristics and ulcer features were evenly distributed. The proportion of ulcers healed within 4 months and the time to completion of healing were recorded. Subjective appraisal was assessed with a validated questionnaire. Results: Complete wound closure was achieved in 70.0% (21 of 30) with bandages and in 96.2% (25 of 26) with the ulcer X kit (p = 0.011). Ulcers with a diameter of up to about 4cm healed twice as rapidly, the larger ones as fast with the stocking kit as with bandages. The sum of problems encountered with bandages was significantly greater than that observed with the stocking kit (p < 0.0001). Pain at night and in the morning was absent with stockings but reported by 40% and 20% in the bandage group, respectively. The cardinal features associated with delayed or absent healing were ulcer size and pain. Conclusions: Common venous ulcers can readily be treated with the ulcer X compression kit provided the ankle movement allow its painless donning. Bandages, even when applied by the most experienced staff are less effective and cause more problems.

Country
Italy
Related Organizations
Keywords

Traditionally, venous leg ulcers are treated with firm nonelastic bandages. Medical compression stockings are not the first choice although comparative studies found them equally effective or superior to bandages. Patients, methods: We report on a multi-center randomized trial with 60 patients treated with either short stretch multi-layer bandages or a two-stocking system (Sigvaris® Ulcer X® kit). Three patients have been excluded because their ankle movement was restricted to the extent that they could not put on the stockings and 1 patient withdrew consent. Patient characteristics and ulcer features were evenly distributed. The proportion of ulcers healed within 4 months and the time to completion of healing were recorded. Subjective appraisal was assessed with a validated questionnaire. Results: Complete wound closure was achieved in 70.0% (21 of 30) with bandages and in 96.2% (25 of 26) with the ulcer X kit (p = 0.011). Ulcers with a diameter of up to about 4cm healed twice as rapidly, the larger ones as fast with the stocking kit as with bandages. The sum of problems encountered with bandages was significantly greater than that observed with the stocking kit (p < 0.0001). Pain at night and in the morning was absent with stockings but reported by 40% and 20% in the bandage group, respectively. The cardinal features associated with delayed or absent healing were ulcer size and pain. Conclusions: Common venous ulcers can readily be treated with the ulcer X compression kit provided the ankle movement allow its painless donning. Bandages, even when applied by the most experienced staff are less effective and cause more problems., Cardiology and Cardiovascular Medicine

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!