Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Tension-free vaginal tape and percutaneous vaginal tape sling procedures.

Authors: R R, Rackley; J B, Abdelmalak; M B, Tchetgen; S, Madjar; S, Jones; M, Noble;

Tension-free vaginal tape and percutaneous vaginal tape sling procedures.

Abstract

Midurethral synthetic sling procedures for treatment of stress urinary incontinence (SUI) are gaining increased attention from surgeons specializing in female pelvic reconstructive techniques seeking successful patient outcomes through reproducible simplicity. This report describes the procedural steps and methods used to maximize the potential for successful outcomes using techniques of midurethral synthetic sling placement. Reported complications and surgical outcomes are reviewed with respect to patient selection and minimizing the potential for morbidity and mortality as long-term clinical experience is accumulated.Tension-free vaginal or transvaginal tape (TVT) and the recently introduced percutaneous vaginal tape (PVT) are two new procedural choices for placement of synthetic sling material at the midurethra. Both procedures use sling material composed of polypropylene mesh, a nonabsorbable synthetic material, placed at the level of the midurethra via an antegrade (PVT, using a percutaneous ligature carrier) suprapubic approach or retrograde (TVT, using vaginal trocars) vaginal approach. Patient selection, procedural techniques, and methods described are based on observations obtained or reported from clinical experience. Outcomes and complications for TVT are derived from a literature review of all published articles in Index Medicus from 1996 to 2000.The experience with TVT for the last 5 years is encouraging. At 3-year follow-up for TVT, reported cure rates for SUI range from 80% to 95%. A multitude of worldwide reports on PVT with shorter follow-up support the findings of the TVT experience. Reproducible findings with midurethral synthetic slings are the short operative times recorded for the sling procedure, ease of technical performance, minimal patient discomfort, and a high rate of early return of normal voiding function. The rate of complications such as obstructive voiding or de novo instability (0-15%) and urinary retention necessitating a secondary procedure (2-4%) appear to be equal to the rates of contemporary competing technologies and procedures for treatment of SUI.Preliminary reports and the experience at our institution suggest that the techniques of midurethral synthetic sling placement of TVT and PVT are reproducible, easy to master, and minimally invasive with respect to tissue handling. Although complications with all anti-incontinence procedures exist, understanding the anatomical considerations and methodology of these unique procedures should minimize patient morbidity, avoid patient mortality, and produce a high rate of durable success.

Keywords

Prosthesis Implantation, Urethra, Patient Selection, Urinary Incontinence, Stress, Humans, Urologic Surgical Procedures, Female, Prostheses and Implants, Surgical Mesh, Polypropylenes

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!