Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Canada Researcharrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
Canada Research
Thesis . 2011
Data sources: Canada Research
MacSphere
Thesis . 2014
Data sources: MacSphere
versions View all 2 versions
addClaim

Magnetic Resonance Elastography

Authors: Saeed, Farukh;

Magnetic Resonance Elastography

Abstract

This thesis is composed of six chapters. First MRE is briefly introduced together with some relevant literature in Chapter one. The second chapter is about the principles and theory of magnetic resonance imaging, with the MRE theory, software and hardware addressed in Chapter 3. Chapters 4 and 5 describe the hardware design, software programming, experimental setup and elasticity reconstruction. Chapter 6 is a general discussion, introducing challenges and future directions. A vibration actuator and coil was designed and constructed, then combined with the necessary hardware required to induce the motion in the actuator. A Gradient Echo pulse sequence was modified using the Siemens IDEA environment for MRE application. A phantom was made with concentrations of 1%, 2%, and 3% agar gel. The phantom was scanned using the MRE sequence while inducing the propagating waves. Waves were selected to have frequencies of 125 Hz and 250 Hz. Magnitude and phase images acquired at these frequencies were used to construct the elasticity map using the MRE/Wave reconstruction software. Mean Shear Modulus measured in 1% gel cylinder is 10 kPa and standard deviation (SD) is 6 kPa. Mean elasticity value measured in 3% gel is 49 kPa and SD is 9 kPa. Mean value measured in the background which is 2% gel is 28 kPa and SD is 6 kPa. The results obtained are comparable to the values calculated in literature.

Master of Applied Science (MASc)

Country
Canada
Related Organizations
Keywords

MRE, Elastography, Elasticity, Biomedical Engineering and Bioengineering

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Related to Research communities
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!