handle: 11368/2329431
Power quality aspects are becoming more and more challenging in the AES field. Among them, voltage-THD requirements stated by ship-owners are becoming narrower and narrower, while traditional countermeasures to harmonic distortion do not seem to completely meet such demands any more. The paper presents the employment of MV active filters as a mean for solving the problem of on board voltage harmonic distortion. Points of strength of this proposal are discussed and its application on an all-electric cruise liner is described. Outstanding performance can be achieved as far as new power devices are made available by the market.
Active filter, harmonic, Active filter; harmonics; multilevel converter, multilevel converter
Active filter, harmonic, Active filter; harmonics; multilevel converter, multilevel converter
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |