handle: 11311/1119048
In the present paper, an experimental study of the use of R290 in an ice maker is presented. The analysis deals with a vapour compression system that originally works with R404A and produces 85 kg per day of ice with water inlet temperature equal to 10 °C and air temperature equal to 10 °C. A redesign of the system is carried out to reduce internal volume, allowing the system to be charged with less than 150 g of R290 as per international standards. The experimental results show that, in the range of the testing conditions, the ice production reduces a little, from 0.30% to 5.45% whereas the specific electric consumption significantly reduces, with measured value from 14.46% to 21.23% lower than those of R404A system. Therefore, R290 is a good candidate for refrigerant substitution in this kind of systems.
Energy Efficiency, Ice Maker, Propane, Refrigerant Charge
Energy Efficiency, Ice Maker, Propane, Refrigerant Charge
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |