Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Norwegian Open Resea...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
USN Open Archive
Doctoral thesis . 2015
Data sources: USN Open Archive
versions View all 2 versions
addClaim

Tomographic Approach to Automatic and Non-Invasive Flow Regime Identification

Authors: Pradeep, Chaminda;

Tomographic Approach to Automatic and Non-Invasive Flow Regime Identification

Abstract

This thesis mainly presents the use of process tomography to study and measure flow parameters in two phase horizontal and near horizontal flows. All static measurements were made using a horizontal separator section while dynamic flow measurements were performed using the flow facility at Telemark University College. Most of the study was based on Electrical Capacitance Tomography (ECT) and Electrical Resistance Tomography (ERT) measurements. Unlike typical tomographic applications, here, the focus was on extracting information from measurements and not constructed tomograms. Artificial Neural Network (ANN) algorithms based inferential models were first developed for interface level estimation of layered flows. The results were tested and validated with both static and dynamic measurements. Separate models for oil-air, water-air and oil-water two phase combinations were developed to compare with the measurements. After having very satisfactory estimations with 12 electrode sensor data, the study was extended with the possible reduced number of electrode sensors. Here the selections were 6, 5 and 4 selected electrode combinations. Corresponding measurements of the selected electrodes were employed in the estimations. The speed of the estimation with the reduction of electrode of the sensor was also studied separately. The experimental analysis demonstrates that interface estimates of the layered flows are possible with ANN based algorithms. It is further evident that even with the reduced 6, 5 and 4 electrode sensor arrangements, acceptable results can be observed quickly but with some increased uncertainty. The possibility of using as a redundant system is also an added advantage of having this type of estimators separately. Some Gamma measurement results presented by (Vestøl 2013) were tested with the ECT tomographic technique. Here, tomograms were used in this study. For oil-air two phase flows the comparisons were acceptable despite the low resolution with ECT. But, ECT does not produce acceptable tomograms when water was the dominant medium. Slug flow parameters, such as slug translational velocity, slug front and tail velocities, liquid film thickness, slug frequency and slug length, were estimated using ECT and ERT measurements. The cross-correlation technique was used in the slug translational velocity calculation. This calculated slug translational velocity, then used in the other parameter estimations. Highspeed camera images captured provided that the estimations are acceptable, though the capturing frequency (100Hz) is not high enough. Time series of differential pressure measurements were also captured along with the tomographic measurements for the verification purpose. They were separately studied with different techniques for the slug flow parameter estimations. Power Spectral Density (PSD) was applied in the calculation of slug frequency. Results show a good agreement between ECT and ERT based estimations and differential pressure based calculations. Possible use of capacitance measurement data matrix properties for the flow regime detection was tested with experimental data. Here independent capacitance measurements of each frame are arranged in a symmetric matrix and the eigenvalues of them are calculated. How the eigenvalues are related to the flow parameters such as liquid fractions are studied here. A good agreement with both measurement data and mathematical model based results are given by (Fang & Cumberbatch 2005). A solid relationship between leading eigenvalue and the volume fractions could be observed. Possible identifications of flow regimes with the second and third dominant eigenvalues were also discussed with the experimental results. Dynamic time warping technique which is commonly applied to align two time series signals are used in the liquid slug length estimations. The fusion of both tomometric and differential pressure measurements is done with this approach. Then, the relationship between liquid slug length and warped pressure peak was also investigated. The relationship between differential pressure and liquid slug length could be identified as linear. The results are proven with different experimental data.

Country
Norway
Related Organizations
Keywords

electrical capacitance tomography, multiphase flow, 553

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green