image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Norwegian Open Resea...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 1 versions
addClaim

Modelling and Control of Six-Phase Induction Motor Drive

Authors: Araya, Nebrom Berihu;

Modelling and Control of Six-Phase Induction Motor Drive

Abstract

Multiphase machines are of interest to be applied in electric ship propulsion, where increased power ratings, reliability of operation, redundancy and efficiency are required. The study of modelling and control of multiphase drives is important to realize this application. The main purpose of this thesis was to implement and test control methods for a six-phase induction motor drive. The work focused on continuation and improvement of previous results achieved in the same area of application. The modelling of six-phase induction machine using two different approaches was studied. Based on these approaches, two types of vector control methods were implemented. These are single synchronous frame control (SSFC) and double synchronous frame control (DSFC). The six-phase induction motor drive was tested for different operating conditions using the two control methods. The motor is normally supplied from two inverters with a split DC link. The DC link voltages are kept equal and the two 3-phase groups of the motor share the torque and power equally. Testing the drive during normal operation showed desired control performance using both SSFC and DSFC methods. Asymmetrical operation of the drive was also investigated. In this case, the currents in the two 3-phase groups of the six-phase motor are unequal. Thus, both do not have equal contribution to the torque developed in the motor. The results obtained using SSFC and DSFC are as desired in both torque control and speed control modes. The third case of interest in the drive testing was the investigation of supply asymmetries and faults. During under-voltage in one DC link, failure of one rectifier, or trip of one inverter, the DSFC method gave desired response in both torque control and speed control modes. Similar results were obtained using SSFC except for the case of inverter trip during speed control mode. From the results obtained, it was concluded that both SSFC and DSFC methods give desired performance during normal operation of the drive. This is also the case for current asymmetries in the motor when there are no supply faults. In the case of supply faults, the DSFC method gave better control of the drive. The DSFC method was also found to be simpler to implement and less computationally demanding.

Keywords

Master of Science in Electric Power Engineering

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Green