Polarimetric thermal imaging

Authors: Loo, Fook Leong;

Polarimetric thermal imaging

Abstract

Passive infrared (IR) imagers, using intensity contrast for target detection, are often limited by low target-background contrast. Detecting stationary targets against cluttered backgrounds presents an even bigger challenge. Polarized signatures can be used as an additional discriminator, to improve target detection probability and reduce false alarm rate. In this research, a polarmetric thermal imager, operating in the mid wave infrared (3-5 U), was set up using the Merlin InSb camera with three internal wire grid polarizers. Non uniformity correction and radiometric calibration were performed to compensate for differences in detector response and polarizer's transmittance. The scene consisted of a heated aluminum plate in front of a large area blackbody as background. The viewing angle, defined as the angle between surface normal and camera angle of sight, was varied by rotating the plate about its vertical axis. Stokes parameters were computed from the irradiance images. Images of intensity, degree of polarization and polarization angle were derived from the Stokes parameters. The dependence of these polarization characteristics on viewing angle was investigated. While intensity increased slightly with viewing angle, degree of polarization increased rapidly when the viewing angle was increased from 20 degrees to 80 degrees. The polarization angle increased with viewing angle and became constant at 150 degrees for viewing angle greater than 60 degrees. Target to background contrast based on degree of polarization increased with viewing angle and was higher than intensity contrast for viewing angle greater than 20 degrees. Image processing algorithms were developed to segment the target plate from its background. The target similarity metric used was the texture-based Fisher distance, which enabled the fusion of one or more data type. The performance of the fusion schemes was compared via their Receiver Opening Characteristic (ROC) curves, which were plots of segmentation accuracy against false alarm rate. Binary image of the target was obtained by applying a Constant False Alarm Rate (CFAR) threshold. Fusion of intensity and polarization data produced better segmentation accuracy and lower false alarm rate than intensity-only data, for plate at viewing angle greater than 60 degrees.

Approved for public release; distribution is unlimited.

Singapore DSO National Laboratories author (civilian).

http://archive.org/details/polarimetricrmal109453563

Keywords

Polarimetric remote sensing, Infrared imaging

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!