Operating air pressure of disposable angles.

Authors: D P, Warren; H C, Rice; D K, McKitrick; J A, McWherter; J M, Powers;

Operating air pressure of disposable angles.

Abstract

This study was conducted to determine if air pressure of 20 pounds per square inch (psi) was sufficient to operate disposable prophylaxis angles smoothly and efficiently without stalling.Five specimens of 15 types of disposable angles were evaluated by four dental hygienists to determine the minimum speed required for smooth operation. A fifth person operated the rheostat and increased the air pressure psi until signaled by the operators to stop once reaching a sufficient air pressure for operating the angle without stalling. Air pressure values were recorded for each test. Means and standard deviations were calculated for all raters for each angle. Data were analyzed using a two-way analysis of variance. Since there were no significant trends among raters, data for raters were combined for each angle and analyzed by a one-way analysis of variance. The Tukey-Kramer interval at a 0.05 significance level for comparisons among angles was determined.Study results showed that air pressure to achieve minimum speed required for smooth operation varied among the angles from 16.8 psi to 28.8 psi. The mean air pressure was 23.0 psi for angles with firm cups, 20.3 psi with soft cups, and 18.0 psi with regular cups. Some soft cup angles required air pressure greater than 20 psi while some firm cup angles required less than 20 psi. The regular flexibility of cup angles tested required less air pressure than 20 psi.The minimum air pressure psi required for smooth operation of disposable angles varied. Generally, air pressure greater than 20 psi was required to operate angles with firm cups, while less than 20 psi was required to operate angles with soft or regular cups.

Keywords

Air Pressure, Analysis of Variance, Dental Prophylaxis, Humans, Disposable Equipment, Dental High-Speed Equipment

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!