Out-of-field doses are delivery to healthy tissues, which may allow the development of second tumours. Its evaluation with MC methods is essential since these doses are inaccurate when calculated by TPSs. The use of IMRT has been discussed, especially in paediatric patients, as it leads to a "bath" of low doses to large volumes of out-of-field tissue. This study aims to evaluate out-of-field doses in paediatric tumours by comparing 3DCRT and IMRT techniques. Thus, a computer model of a LINAC, as well as its 6 MV energy photon beam, and MLC, were initially modelled and validated in MCNP6. Subsequently, CT images of a paediatric anthropomorphic phantom were acquired in IPOLFG and with the ImageJ program; a voxelized paediatric computational phantom was created. Two dosimetric plans were performed, one with the 3DCRT technique and the other with the IMRT technique. Experimental measurements were carried out in LINAC with the paediatric anthropomorphic phantom and with TLDs reproducing the treatment plans previously created in TPS. In the MCNP6 program, the model of the LINAC was added in an unprecedented way, with its MLC and the 6 MV energy photon beam, as well as the previously created voxelized phantom and the out-of-field doses for all organs were calculated for both techniques. The results have shown that out-of-field doses can be seriously underestimated with TPSs. The out-of-field doses are higher when using the IMRT technique (right eye = 13040.6 mGy), compared to the 3DCRT technique (right eye = 593 mGy). This thesis demonstrates a powerful combination of (1) dosimetric measurements in a clinical environment, (2) modelling of a LINAC, treatment beam and MLC, (3) out-of-field organ doses in a paediatric phantom, (4) creation of a voxelized paediatric phantom. This could have an impact in radiological protection and dosimetry in radiotherapy services.
Bolsa de doutoramento Caixa Geral de Depósitos/IPL-2017
Radioterapia, Radiotherapy, Monte Carlo Simulations, Simulações Monte Carlo, Fantoma de Voxel Computacionais, Doses Fora dos Campos de Tratamento, Computational Voxel Phantoms, Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Médica, Paediatric Tumours, Out-of-field Doses, Tumores Pediátricos
Radioterapia, Radiotherapy, Monte Carlo Simulations, Simulações Monte Carlo, Fantoma de Voxel Computacionais, Doses Fora dos Campos de Tratamento, Computational Voxel Phantoms, Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Médica, Paediatric Tumours, Out-of-field Doses, Tumores Pediátricos
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |