image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Archivio Istituziona...arrow_drop_down
image/svg+xml Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao Closed Access logo, derived from PLoS Open Access logo. This version with transparent background. http://commons.wikimedia.org/wiki/File:Closed_Access_logo_transparent.svg Jakob Voss, based on art designer at PLoS, modified by Wikipedia users Nina and Beao
versions View all 3 versions
addClaim

The hemodynamic effects of double-orifice valve repair for mitral regurgitation: a 3D computational model.

Authors: MAISANO F.; REDAELLI, ALBERTO CESARE LUIGI; PENNATI, GIANCARLO; FUMERO, ROBERTO; TORRACCA L.; OTTAVIO ALFIERI O.;

The hemodynamic effects of double-orifice valve repair for mitral regurgitation: a 3D computational model.

Abstract

A 3D computational model has been implemented for the evaluation of the hemodynamics of the double orifice repair. Critical issues for surgical decision making and echo-Doppler evaluation of the results of the procedure are investigated.A parametric 3D computational model of the double-orifice mitral valve based on the finite elements model has been constructed from clinical data. Nine different geometries were investigated, corresponding to three total inflow areas (1.5, 2.25 and 3 cm2) and to three orifice configurations (two equal orifices, two orifices of different areas, i.e. one twice as much the other one, and a single orifice). The simulations were performed in transit; the fluid was initially quiescent and was accelerated to the maximum flow rate with a cubic function. For each case, some characteristic values of velocity and pressure were determined: velocities were calculated downstream of each orifice, at the centre of it (Vcen1, Vcen2). The maximum velocity was also determined for each orifice (Vmax1, Vmax2). Maximum pressure drops (deltap(max)) across the valve were compared with the estimations (deltap(Bernoulli)) based on the Bernoulli formula (4 V2).In each simulation, no notable difference was observed between Vcen1 and Vcen2, and between Vmax1 and Vmax2, regardless of the valve configuration. Maximum velocity and deltap(max) were related to the total orifice area and were not influenced by the orifice configuration. Deltap(Bernoulli) calculated with Vmax was well correlated with the deltap(max) obtained throughout the simulations (y = 0.9126x + 0.3464, r = 0.996); on the contrary the pressure drops estimated using Vcen underestimated (y = 0.6757x + 0.3073, r = 0.999) the actual pressure drops.The hemodynamic behaviour of a double orifice mitral valve does not differ from that of a physiological valve of same total area: pressure drops and flow velocity across the valve are not influenced by the configuration of the valve. Echo Doppler estimation of the maximum velocities is a reliable method for the calculation of pressure gradients across the repaired valve.

Country
Italy
Keywords

Hemodynamics, Models, Cardiovascular, Mitral Valve Insufficiency, Echocardiography, Doppler, Treatment Outcome, Humans, Computer Simulation, Postoperative Period, Cardiac Surgical Procedures, Blood Flow Velocity

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    65
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
65
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!