Downloads provided by UsageCounts
handle: 10261/7808 , 11441/77500
We present a 32 32 pixels contrast retina microchip that provides its output as an address event representation (AER) stream. Spatial contrast is computed as the ratio between pixel photocurrent and a local average between neighboring pixels obtained with a diffuser network. This current-based computation produces an important amount of mismatch between neighboring pixels, because the currents can be as low as a few pico-amperes. Consequently, a compact calibration circuitry has been included to trimm each pixel. Measurements show a reduction in mismatch standard deviation from 57% to 6.6% (indoor light). The paper describes the design of the pixel with its spatial contrast computation and calibration sections. About one third of pixel area is used for a 5-bit calibration circuit. Area of pixel is 58 m 56 m, while its current consumption is about 20 nA at 1-kHz event rate. Extensive experimental results are provided for a prototype fabricated in a standard 0.35- m CMOS process.
This work was supported by Spanish Research Grants TIC2003-08164-C03-01 (SAMANTA), TEC2006-11730-C03-01 (SAMANTA-II), and EU grant IST-2001-34124 (CAVIAR). JCS was supported by the I3P program of the Spanish Research Council. RSG was supported by a national grant from the Spanish Ministry of Education and Science.
Peer reviewed
Analog circuits, Calibration, Address Event Representation (AER), Address-event representation (AER), Artifical retina
Analog circuits, Calibration, Address Event Representation (AER), Address-event representation (AER), Artifical retina
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 80 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 52 | |
| downloads | 105 |

Views provided by UsageCounts
Downloads provided by UsageCounts