Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Recolector de Cienci...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 3 versions
addClaim

Microfluidic device

Authors: Santoro, Gonzalo;

Microfluidic device

Abstract

[ES] Se describe en este documento un dispositivo de microfluídica para SERS. Se describe un dispositivo para la realización de espectroscopía Raman aumentada por superficie o "Surface-Enhanced Raman spectroscopy -SERS" en un canal de microfluídica. Dicho dispositivo constituye una celda de material flexible y compresible, con una ventana óptica, unos adaptadores y medio de bombeo para el control del flujo a través de la celda de microfluídica. El dispositivo objeto de la invención aquí detallada hace uso de los citados adaptadores de tal manera que la ventana óptica permite el paso de luz a la vez que se puede regular el tamaño del canal de microfluídica por el que se hace pasar la solución portadora de muestra de forma continua, mediante un sistema de presión ejercida sobre las paredes del canal

[EN] A microfluidic device for SERS sensing is described herein. A device for performing surface-enhanced Raman spectroscopy (SERS) in a microfluidic channel is described. The device comprises a cell made of a flexible and compressible material with an optical window, adapters and pumping means for controlling the flow through the microfluidic cell. The device which is the subject matter of the invention described in the application uses said adapters such that the optical window allows the passage of light while continuously regulating the size ofthe microfluidic channel through which the sample carrier solution is continuously passed by means of a system that applies pressure to the walls of the channel

A1 Solicitud de patente con informe sobre el estado de la técnica

Consejo Superior de Investigaciones Científicas (España)

Peer reviewed

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 22
    download downloads 51
  • 22
    views
    51
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
22
51
Green