Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Recolector de Cienci...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 1 versions
addClaim

Dual image system suitable for oncological diagnoses and real time guided biopsies

Authors: Caballero Ontanaya, Luis; Domingo Pardo, César; Albiol Colomer, Francisco;

Dual image system suitable for oncological diagnoses and real time guided biopsies

Abstract

La invención se refiere a un sistema de imagen dual, apto para su uso en diagnósticos oncológicos y biopsias guiadas en tiempo real, que comprende: un dispositivo de imagen por ultrasonidos (1) para la obtención de señales asociadas a una o más imágenes anatómicas; un detector de rayos gamma (2) para la obtención de señales asociadas a una o más imágenes funcionales; un módulo de electrónica (3) para procesar las señales obtenidas por los detectores (1, 2); una carcasa (4) que aloja los detectores (1, 2); caracterizado por que el detector de rayos gamma (2) es un detector de dispersión Compton de rayos gamma, que comprende al menos dos detectores individuales (2a, 2b) gamma alineados sustancialmente en la misma dirección de detección y con planos de detección sustancialmente paralelos entre sí; el dispositivo de imagen por ultrasonidos (1) y el detector de rayos gamma (2) poseen unas direcciones de detección sustancialmente alineadas entre sí. [ES]

The present invention relates to a dual image system, suitable for oncological diagnoses and real time guided biopsies, comprising: an ultrasound imaging device (1) for obtaining signals associated with one or more anatomical images; a gamma ray detector (2) for obtaining signals associated with one or more functional images; an electronic module (3) for processing the signals obtained by the detectors (1, 2); a casing (4) housing the detectors (1, 2); characterized in that the gamma ray detector (2) is a gamma ray Compton scattering detector, comprising at least two individual gamma detectors (2a, 2b) aligned substantially in the same detection direction and with the detection surfaces substantially parallel to each other; the ultrasound imaging device (1) and the gamma ray detector (2) have detection directions substantially aligned with each other. [EN]

Consejo Superior de Investigaciones Científicas, Universitat de València

A1 Solicitud de patente con informe sobre el estado de la técnica

Peer reviewed

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 90
    download downloads 138
  • 90
    views
    138
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
0
Average
Average
Average
90
138
Green