Views provided by UsageCounts
handle: 10261/22547 , 20.500.14243/431146
In support of the implementation of the European Union (EU) Water Framework Directive (WFD), the European Commission (EC) Joint Research Centre (JRC) organized a laboratory and sampling intercomparison study for the chemical monitoring of polyaromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs), and nonylphenol and octylphenol (NP/OP), priority substances of the WFD, in river water. EU Member State laboratories were invited to analyze a standard solution with unknown concentration levels and a river-water extract, as well as a real water sample from the River Po (Italy). For the standard solution and the river-water extract, good agreement was achieved for five laboratories. Triple-quadrupole liquid chromatography with tandem mass spectrometry (LC-MS2) and gas chromatography with MS (GC-MS) with or without derivatization proved to be comparable methods for the analysis of NP and OP. Fluorescence detection can also be used to analyze NP and OP, but it is less specific. The results of the River Po water sample showed that some laboratories have problems in analyzing NP at concentration levels below 100 ng/L due to contamination of laboratory blanks. Plastics materials should not be used during extraction and sample preparation.
Without the effort of the participating laboratories, this article would not have been possible. Susanne Boutrup, Stefano Polesello and Joan Staeb have given very helpful comments on the manuscript. Stefano Polesello is especially thanked for the help with the OP standards. Moreover, we would like to thank the “Servizio Risorse Idriche e Tutela Ambientale della Provincia di Ferrara” (Silvano Bencivelli, Paola Magri), Lars Håkanson, Graziella Leroy and Madeleine Rizzi.
7 pages, 4 figures, 2 tables.-- Available online Oct 30, 2007.
Peer reviewed
Octylphenol, Laboratory intercomparison, Quality control, QA/QC, Nonylphenol, Quality assurance, Sampling intercomparison, Proficiency testing, Priority substance, Water Framework Directive
Octylphenol, Laboratory intercomparison, Quality control, QA/QC, Nonylphenol, Quality assurance, Sampling intercomparison, Proficiency testing, Priority substance, Water Framework Directive
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 37 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 57 |

Views provided by UsageCounts