handle: 10261/221861
The LA-ICP-MS technique has been evaluated with respect to applications relevant for the steel industry, with special emphasis on spatially resolved analysis. Three different commercially available laser ablation units have been used, CETAC LSX 100, CETAC LSX 200 and new wave research UP 213. The work on bulk steel analysis showed that sample preparation is not critical for the intensity and stability of the analytical signals. Combined with the extraordinary flexibility in terms of sample size and shape, this confirms that LA ICP-MS is a very practical technique in terms of sampling. Evaluating the analytical figures of merit in bulk analysis (accuracy, precision, detection limits) it is again clear that, as with the wet ICP-MS, the strength of the technique is the low DLs for a wide range of elements. The accuracy and precision for determinations of alloying and major elements fall far short of conventional techniques such as spark OES and XRF. However, LA ICP-MS is not being developed to become an alternative to these techniques for routine bulk analysis. The major emphasis in this project was on spatially resolved analysis. It was found that the very best lateral resolution obtained in practice with commercially available systems is about 40 μm. However, a major limitation in time is imposed by the slow response of the sample transport systems if demands on lateral resolution are high. During the project work, it has become clear that all commercially available systems are basically well designed and functional. However, the complete system with laser ablation unit and ICP-MS system is still quite demanding in terms of practical handling, tuning for optimised signals etc. It was also found that the software delivered by the instrument manufacturers is still inadequate for making full use of the analytical potential of the technique. The powerful capability for spatially resolved analysis that was demonstrated, both in the form of linescans and 2-D mapping, is not matched by easy-to-use software to evaluate (quantify) and display the results graphically. Introduction of such software in commercial systems would probably increase the interest in the technique substantially.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |