Herein we report a Prussian Blue modified carbon fiber electrode (CFE/PB) to be used in microbiosensors for glutamate monitoring in physiological applications as an alternative to the classical Pt and Pt-Ir transducers. Their low dimensions (∼250 μm CFE length and ∼10 μm diameter) are advantageous for measuring in living tissues. In addition, PB-modified microelectrodes allow the detection of enzyme-generated hydrogen peroxide at a low applied potential (∼0.0 V against SCE), contrasting the high potential used in many previous designs (∼0.7 V), decreasing the endogenous interference contributions. Moreover, the electrosynthesized polymer, poly-o-phenylenediamine (PoPD), was used to improve biosensor stability and selectivity. CFE/PB was conveniently characterized using impedance, Raman and XPS spectroscopies. Optimization of the fabrication procedure and analytical conditions is described, including activation of CFE/PB, enzyme enrichment, cross-linking, stabilization and anti-interference. A range of analytical parameters were also characterized such as sensitivity, limit of detection, linear range, and enzymatic loading. Finally, an optimized biosensor displaying a linear sensitivity of 135 ± 2 nA μM cm (n = 3), LOD of <2 μM, linear range up to 150 μM and effectively free of interference, is proposed as a suitable candidate for in-vivo glutamate monitoring in the central nervous system.
This research was supported by the grant INNPACTO-MINECO (IPT-2012-0961-300000), Ministerio de Ciencia e Innovación (TIN2011-28146), project RECUPERA 2020 from MINECO and the “Fondo social Europeo”, project MAT2013-40852-R and MAT2013-42900-P from MINECO and TEP8067 and FQM6900 from the Junta de Andalucía.
Biosensors, Poly-o-phenylenediamine, Prussian blue, Neurochemistry, Glutamate, Carbon fiber electrode
Biosensors, Poly-o-phenylenediamine, Prussian blue, Neurochemistry, Glutamate, Carbon fiber electrode
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 39 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 39 | |
| downloads | 21 |

Views provided by UsageCounts
Downloads provided by UsageCounts