doi: 10.82308/52583
A thin-webbed welded steel plate girder (h/t = 370:1) was tested up to an average shear stress of 13 ksi, or three times the Timoshenko critical load. Local yielding occurred during the initial loading, but subsequent performance was elastic. Strains were recorded in two panels (d/h = 0.5) subjected to combined shear and bending, and in the adjacent stiffeners and flanges.
De Stein, J. (Supervisor)
Civil Engineering and Applied Mechanics
Civil Engineering and Applied Mechanics
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |