Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Fire Science and Eng...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Fire Science and Engineering
Article . 2025 . Peer-reviewed
License: CC BY NC
Data sources: Crossref
addClaim

Study on the Effectiveness of Water Curtain Systems in Delaying the Spread of Fire in Factory Buildings

Authors: Jin-Suk Kwon; Tae-Sun Kim; Tae-Hee Park; Tae-Dong Kim; Ji-Hyun Yang; Yeong-jin Kwon;

Study on the Effectiveness of Water Curtain Systems in Delaying the Spread of Fire in Factory Buildings

Abstract

Domestically constructed factory buildings have narrow spacing between structures, which makes them vulnerable to fires spreading to adjacent buildings. Additionally, these buildings often use temporary construction materials that are easy to install, leading to significant loss of life and property damage during fire spreading. When responding to a fire in a factory building, firefighters focus on extinguishing the fire at its source while implementing defensive water-supply measures to prevent its spread to adjacent buildings. In this study, we confirmed the effectiveness of a water-barrier system installed on the exterior walls of factory buildings as a replacement for firefighters’ defensive water-supply systems in the event of a fire. Under conditions simulating a factory fire, the radiant heat and core temperatures of sandwich panels on the exterior walls of factory buildings were measured while varying the nozzle types and separation distances of the water curtain systems. The results of the experiments showed that despite differences depending on the type of nozzle, the radiant heat decreased from 24.83 kW/m<sub>2</sub> to 33.09 kW/m<sub>2</sub>, and the core temperature of the panels decreased from approximately 2.2 °C to 13 °C. Among these, nozzle B, which used approximately one-fourth of the water compared with the existing drencher nozzle, was found to be suitable for on-site applications. Based on these results, further studies will be conducted to develop the most suitable nozzle for water-film systems.

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
hybrid