
doi: 10.7577/radopen.3565
Keywords: Effective dose, Dose Length Product, Computed Tomography Dose Indexvolume, Dose Reference Level AbstractAim: The aim of this study was to estimate the effective doses from CT scans using DoseLength Product (DLP) in a Nepalese hospital.Materials and methods: This prospective study was conducted in 150 patients above 18years of age who were referred for CT scan of head, chest and abdomen. The CT scan wasperformed on a 128 slice multi detector scanner. All the subjects who met the inclusioncriteria were included in the study. Following the non-contrast imaging phases of the head,chest and abdomen CTDIvol, DLP, kVp and pitch were recorded for each patient from theconsole display of the scanner. The effective dose was calculated for each examination usingDLP which were graphically analyzed and correlated with the age of the patient.Results: The study showed the mean CTDIvol for head, chest and abdomen to be 53.95±4.83mGy, 5.28±1.17 mGy and 11.15±2.71 mGy respectively along with mean DLP to be923.52±71.11 mGycm, 229.32±48.70 mGycm and 517.02±148.32 mGycm respectively. Usingthese values, the mean effective doses were calculated and found to be 1.93±0.14 mSv,3.20±0.68 mSv and 7.75±2.19 mSv respectively.Conclusion: The calculated effective dose values were lower than in other studies for CTexaminations of chest and abdomen while higher or similar for CT examination of head. Theresults of this survey could motivate other researchers to investigate the radiation doses inother hospitals and help establish national diagnostic reference levels.
Medical physics. Medical radiology. Nuclear medicine, R895-920
Medical physics. Medical radiology. Nuclear medicine, R895-920
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
