Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Japanese Journal of ...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Japanese Journal of Radiological Technology
Article . 2016 . Peer-reviewed
Data sources: Crossref
versions View all 2 versions
addClaim

Dosimetric Verification around High-density Materials for External Beam Radiotherapy

外部放射線治療における高密度物質周辺部の線量計算精度検証
Authors: Makoto, Sasaki; Manabu, Nakata; Mitsuhiro, Nakamura; Yoshitomo, Ishihara; Takahiro, Fujimoto; Yusuke, Tsuruta; Shinsuke, Yano; +1 Authors

Dosimetric Verification around High-density Materials for External Beam Radiotherapy

Abstract

It is generally known that the dose distribution around the high-density materials is not accurate with commercially available radiation treatment planning systems (RTPS). Recently, Acuros XB (AXB) has been clinically available for dose calculation algorithm. The AXB is based on the linear Boltzmann transport equation - the governing equation - that describes the distribution of radiation particles resulting from their interactions with matter. The purpose of this study was to evaluate the dose calculation accuracy around high-density materials for AXB under three X-rays energy on the basis of measured values with EBT3 and compare AXB with various dose calculation algorithms (AAA, XVMC) in RTPS and Monte Carlo. First, two different metals, including titanium and stainless steel, were inserted at the center of a water-equivalent phantom, and the depth dose was measured with EBT3. Next, after a phantom which reproduced the geometry of measurement was virtually created in RTPS, dose distributions were calculated with three commercially available algorithms (AXB, AAA, and XVMC) and MC. The calculated doses were then compared with the measured ones. As a result, compared to other algorithms, it was found that the dose calculation accuracy of AXB at the exit side of high-density materials was comparable to that of MC and measured value with EBT3. However, note that AXB underestimated the dose up to approximately 30% at the plane of incidence because it cannot exactly estimate the impact of the backscatter.

Related Organizations
Keywords

Phantoms, Imaging, Radiotherapy Dosage, Radiometry, Monte Carlo Method, Algorithms

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    1
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
1
Average
Average
Average
bronze