Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

Corrosion Monitoring in Dehumidified Storage

Authors: Elizabeth Trillo; Leonardo Caseres;

Corrosion Monitoring in Dehumidified Storage

Abstract

Abstract Dehumidified storage areas are designed to eliminate moisture and thereby corrosion damage. The goal of a dehumidified storage system is to keep the relative humidity (RH) below a certain level (75%) whereby the adverse effects of humidity (rust, condensation, mold and mildew) are greatly reduced or eliminated. In this study, monitoring sensors were placed inside storage facilities with and without a dehumidification system. The corrosion behavior, temperature and relative humidity were measured using a multielectrode array sensor (MAS) and coating degradation sensor (CDS) systems and compared to conditions that were outside the storage facility. The results of the program show that, the relative humidity was low both inside a thermal insulated storage facility (without dehumidification) and inside a tensioned fabric shelter (with dehumidification). Low corrosion rates were observed inside the thermal insulated storage building without dehumidification. In addition, the impedance values were high (potential for corrosion was low) for the tensioned fabric shelter with dehumidification. The RH and corrosion rates were highest in the outside condition (open lot) environment. Corrosion monitoring systems thus assist in identifying conditions where corrosion is most likely to occur as well as determine where dehumidification systems are necessary or not, thereby improving operational costs.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!