Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

EVAPORATIVE COOLING

Authors: HERBERT C HARRISON;

EVAPORATIVE COOLING

Abstract

<div class="htmlview paragraph">First taking exception to the term “steam cooling” because of its association with steam heating, and suggesting “evaporative cooling” as more appropriate, the author describes the results of 7 years' experimentation with various modifications of an original system and declares that the latter has proved itself to be the most satisfactory.</div> <div class="htmlview paragraph">The problem is stated to be merely that of cooling an internal-combustion engine with boiling water, using the water as a carrier of the steam produced to transfer the very considerable quantity of heat contained in the steam to a system suitable for condensing the steam and wasting its latent heat by condensation.</div> <div class="htmlview paragraph">After detailing the many shortcomings of the conventional water-cooled system, which include the liability of the system to become stagnant because of the formation of steam-pockets and the consequent inoperativeness of the pump; the excessive size of the radiator required to meet the maximum demand while running with wide-open throttle, at maximum possible speed, in a hot climate, or at a great altitude; the unsuitability of such a radiator for normal operation during the greater part of the year; and the problem of crankcase-oil dilution due to overcooling, the advantages of evaporative cooling are outlined.</div> <div class="htmlview paragraph">Although the problem of allowing water to boil in the cylinder jackets, the steam formed to be condensed and the condensate to be returned does not seem difficult, many practical considerations must be taken into account.</div> <div class="htmlview paragraph">Experiments with numerous variations of the original system are described, such as operating at a variable or a fixed pressure; at subatmospheric, atmospheric or superatmospheric pressure; with the steam circulating downward as in ordinary radiator practice, from side to side or introduced at the bottom and allowed to flow upward; or with dry steam, wet steam or steam and water.</div> <div class="htmlview paragraph">Of these variations the most satisfactory combination is said to be that in which wet steam containing water is introduced into one side of the radiator-core, the water being allowed to traverse the lower tubes and the steam the upper tubes of the radiator. The steam in crossing the radiator is condensed and trickles down to the water and both are returned by one pump to the cylinder-block.</div> <div class="htmlview paragraph">The general principles said to apply to successful operation include:</div> <div class="htmlview paragraph"> <ol class="list nostyle"> <li class="list-item"> <span class="li-label">(1)</span> <div class="htmlview paragraph">Rapid circulation of water through the jackets into the cooling-system</div> </li> <li class="list-item"> <span class="li-label">(2)</span> <div class="htmlview paragraph">Maximum temperature-difference between the air and the core</div> </li> <li class="list-item"> <span class="li-label">(3)</span> <div class="htmlview paragraph">A centrifugal pump operating with slightly cooled water, a gear-pump being undesirable</div> </li> <li class="list-item"> <span class="li-label">(4)</span> <div class="htmlview paragraph">Prevention of an air-lock in the condenser, and the venting of the cold side of the condenser to the atmosphere</div> </li> <li class="list-item"> <span class="li-label">(5)</span> <div class="htmlview paragraph">Provision for the care of residual heat in the cylinder-block to minimize the loss of steam after hard driving and sudden stopping</div> </li> <li class="list-item"> <span class="li-label">(6)</span> <div class="htmlview paragraph">No loss of water or alcohol under any circumstances</div> </li> <li class="list-item"> <span class="li-label">(7)</span> <div class="htmlview paragraph">No retardation of rate of circulation of steam</div> </li> <li class="list-item"> <span class="li-label">(8)</span> <div class="htmlview paragraph">Air-flow and rise of temperature of the air dependent on the volume of air passed and the turbulence within the radiator</div> </li> <li class="list-item"> <span class="li-label">(9)</span> <div class="htmlview paragraph">Interchangeability of the condenser with a standard radiator</div> </li> <li class="list-item"> <span class="li-label">(10)</span> <div class="htmlview paragraph">Capacity, when fully filled with water, of operating as a superior water-cooled system</div> </li> </ol> </div>

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    5
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
5
Average
Top 10%
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!