Transient Exhaust Gas Recirculation Ratio Measurement Utilizing Heated NDIR Method

Authors: Tomoshi Yoshimura; Masaru Miyai; Hiroshi Nakamura;

Transient Exhaust Gas Recirculation Ratio Measurement Utilizing Heated NDIR Method

Abstract

<div class="section abstract"><div class="htmlview paragraph">Most of the recent clean diesel engines are equipped with an exhaust gas recirculation (EGR) technology in order to meet the strict criteria of NOx and particulate matter (PM) as required in the current emission regulations. More attention to strict EGR control is becoming required. Accurate and fast transient EGR ratio operation is becoming very critical in the field of the emission control.</div><div class="htmlview paragraph">The EGR ratio is typically monitored by CO₂ trace method, in which CO₂ emitted from engine, is utilized as a tracer gas. The EGR ratio can be obtained from CO₂ concentration measured at engine intake and engine out at the same time. In this study, authors have developed a new EGR analyzer consisting of two CO₂ detectors, to achieve required performance for transient measurement, i.e., short delay time and quick response, negligible difference between two CO₂ detectors, and capability of wet measurement. For this new analyzer, heated NDIR detectors which can measure CO₂ in engine emission under wet condition were adopted. The sample lines for each CO₂ detector were configured to have small volume and also almost same design as each other, to avoid transient errors caused by the difference in response time.</div><div class="htmlview paragraph">We have evaluated the performance of the transient EGR analyzer through some comparison tests with a conventional exhaust gas analyzers system. In consequence, the faster response has been observed from the transient EGR analyzer without significant transient error under several test cycles. Furthermore it has proved that effects on response time from the sample inlet pressure change are significantly small. Finally the EGR ratio measured by the transient EGR analyzer followed up the EGR valve operation well. These results show the advantages of the transient EGR analyzer for measuring EGR ratio under transient state.</div></div>

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    4
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
4
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!