Bedside dialysis monitoring equipment for hemodialysis are located in the bioburden section upstream of the endotoxin-retentive filter for dialysis fluid sterilization. We observed 26 equipment at our institution for bacterial contamination at least once every 4 weeks for 5 years with another ultrafiltration membrane upstream to prevent bacterial contamination. Bacterial contamination levels were highest and most diverse at the time of the first flush. During subsequent initial cleanng, the contamination level decreased, and bacterial species converged almost exclusively to one genus, namely Methylobacterium spp. During clinical use, the equipment were cleaned and disinfected daily after dialysis, and daily operations and maintenance were performed using aseptic techniques. Although the frequency of bacterial detection decreased annually, the same bacterial genotypes observed at the first flush were isolated even after long time periods and were thought to persist in the equipment possibly by forming biofilm. Pseudomonas aeruginosa was newly detected after the replacement of parts during breakdown maintenance, indicating the need to sterilize replacement parts. Thus, the bioburden should be assessed regularly as part of the management of in-house-produced dialysis fluid.
breakdown maintenance, Endotoxins, hemodialysis, Bacteria, <i>Methylobacterium</i> spp., Renal Dialysis, Dialysis Solutions, Ultrafiltration, bioburden, biofilm
breakdown maintenance, Endotoxins, hemodialysis, Bacteria, <i>Methylobacterium</i> spp., Renal Dialysis, Dialysis Solutions, Ultrafiltration, bioburden, biofilm
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 4 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |