In the dissolution-dynamic nuclear polarization technique, molecular probes with long T1s are preferred. 13C nuclei of small molecules with no directly bonded protons or sp313C nuclei with proton positions substituted by deuterons may fulfill this requirement. The T1 determination of such new molecular probes is crucial for the success of the hyperpolarized observation. Although the inversion-recovery approach remained by and large the standard for T1 measurements, we show here that the steady-state variable nutation angle approach is faster and may be better suited for the determination of relatively long T1s in thermal equilibrium. Specifically, the T1 of a new molecular probe, [uniformly labeled (UL)-13C6, UL-2H8]2-deoxy-d-glucose, is determined here and compared to that of [UL-13C6, UL-2H7]d-glucose.
Original Research
Original Research
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |