The aim of this study was to evaluate the cyclic fatigue resistance of Reciproc (RCP) and RPC Blue (RCPB) instruments used in continuous rotation, "RECIPROC" mode, and "WAVEONE" mode.Sixty RCP and 60 RCPB R25 files were used. For each file type, three groups (n = 20) were defined depending on the used kinematics: continuous rotation, "RECIPROC" mode, and "WAVEONE" mode. A stainless-steel artificial canal with 60° angle and 5-mm radius of curvature was milled reproducing the size and taper of the used files. The test device was electrically heated to 35°C to simulate the clinical environment. All files were reciprocated or rotated until fracture. The time to failure and the length of the fractured fragments were measured. A fractographic examination was performed by scanning the electron microscopy to confirm the cause of fracture. Collected data underwent a two-way analysis of variance (α = 0.05).RCPB files exhibited better cyclic fatigue resistance than RCP. The "RECIPROC" motion yielded greater cyclic fatigue resistance than the "WAVEONE" movement; the least resistance was observed in the continuous rotation groups. No significant differences were found among groups in terms of length of the fractured fragment. The fractographic analysis confirmed that all scanned samples separated due to cyclic fatigue.Within the limitation of the present study, the "RECIPROC" mode increased the cyclic fatigue resistance of the tested instruments compared to "WAVEONE" mode and continuous rotation. To prevent RCP and RCPB file separation, motion kinematics other than the native "RECIPROC" movement should be discouraged in the clinical setting.
Cyclic fatigue, Cyclic fatigue; Reciproc; Reciproc Blue; reciprocation; scanning electron microscopy, reciprocation, Original Article, Reciproc, Reciproc Blue, scanning electron microscopy
Cyclic fatigue, Cyclic fatigue; Reciproc; Reciproc Blue; reciprocation; scanning electron microscopy, reciprocation, Original Article, Reciproc, Reciproc Blue, scanning electron microscopy
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 5 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |
| views | 68 | |
| downloads | 19 |

Views provided by UsageCounts
Downloads provided by UsageCounts