doi: 10.4028/p-8b9mj9
Due to the importance of the joists slab system as an excellent solution for increasing span demands in different building types, investigating its properties becomes essential for different researchers. The effects of numerous parameters on the structural behaviour of the joists slab system, whether it was a waffle, ripped, or composite sections were reviewed in this paper from past studies. This study aims to determine the most effective parameters for the joist's system loading capacity. The main conclusions were that the slab thickness and joist height were the critical parameters for increasing the load capacity and stiffness of the slab. Furthermore, a small opening in the slab was more efficient in reducing the punching shear effect than larger openings. While providing stiffening rips around the opening was more effective in rose load bearing and reducing deflection than strengthening by carbon fibre sheets.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |