Abstract Objective: The aim of this study was to compare the biomechanical properties of minimal invasive sliding antirotator compressive hip screw (MIS–A–CHS), and multiple cannulated screws (CS) on a Pauwels type 3 femoral neck fracture model. Methods: A Pauwels type 3 vertical femoral neck fractures was created on 12 third-generation proximal femur models which were divided into two equal groups. The fracture was fixed with three CS in the first group, and MIS–A–CHS in the second group. The axial and rotational stiffness and maximum compression effect were compared between the groups. Results: The axial and rotational stiffness and maximum compression were significantly higher in MIS–A–CHS group (912.5 N, 540 N and 10.2 N/m, respectively) than the CS group (627.5N, 380 N, and 3.9 N/m, respectively). Conclusion: MIS–A–CHS appears to be a more secure fixation method in Pauwels type 3 femoral neck fractures than the CS. Özet Çalışma planı: On iki adet üçüncü nesil proksimal femur kemik modelinde Pauwels tip 3 vertikal femur boyun kırığı oluşturuldu ve modeller iki gruba ayrıldı. Birinci gruba üç paralel KV, ikinci gruba MIS–A–CHS ile tespit uygulandı. İki grubun aksiyel ve torsiyonel yüklenmelere karşı dayanıklılıkları ve maksimal kompresyon güçleri hesaplandı ve birbirleri ile karşılaştırıldı. Çıkarımlar: MIS–A–CHS, Pauwels tip 3 femur boyun kırıklarında KV’e göre aksiyel ve torsiyonel kuvvetlere daha dayanıklı olan ve daha fazla kompresyon sağlayan bir tespit yöntemidir.
Models, Anatomic, Comparative Effectiveness Research, Femoral neck fracture, Compressive Hip Screw, Bone Screws, Cannulated Screw, Biomechanical Phenomena, Femoral Neck Fractures, Equipment Failure Analysis, Weight-Bearing, Fracture Fixation, Internal, Torque, Materials Testing, Humans, Femoral Neck Fracture, Biomechanics, Hip Joint, Cerrahi
Models, Anatomic, Comparative Effectiveness Research, Femoral neck fracture, Compressive Hip Screw, Bone Screws, Cannulated Screw, Biomechanical Phenomena, Femoral Neck Fractures, Equipment Failure Analysis, Weight-Bearing, Fracture Fixation, Internal, Torque, Materials Testing, Humans, Femoral Neck Fracture, Biomechanics, Hip Joint, Cerrahi
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 23 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 10% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
| views | 12 | |
| downloads | 7 |

Views provided by UsageCounts
Downloads provided by UsageCounts