Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

The Acoustic Test Environment for Hearing Testing

Authors: Robert H, Margolis; Brandon, Madsen;

The Acoustic Test Environment for Hearing Testing

Abstract

Background:Audiology clinics traditionally employ expensive, prefabricated sound rooms to create an environment that is sufficiently quiet for accurate hearing tests. There is seldom any analysis of the need for or benefit from such enclosures. There may be less expensive methods that would decrease the cost of and increase access to hearing testing.Purpose:This report provides information concerning the need for and effectiveness of sound rooms and an analysis of the audiometric test ranges for various earphone/room combinations.Research Design:Acoustic measurements made in four rooms were analyzed with the attenuation provided by various earphone designs to determine the maximum permissible ambient noise levels and the corresponding audiometric test ranges.Study Sample:The measurements and calculations were performed with four test rooms and five earphone designs.Data Collection and Analysis:Ambient noise levels and earphone attenuation characteristics were used to calculate the noise levels that reach the ear. Those were compared to the maximum permissible ambient noise levels that are provided in ANSI S3.1-1999 or calculated from measured attenuation levels. These measurements were used to calculate testable ranges for each room/earphone combination.Results:The various room/earphone combinations resulted in minimum test levels that ranged from −10 to 20 dB HL at various test frequencies.Conclusions:When the actual benefits of expensive prefabricated sound rooms are assessed based on the range of hearing levels that can be tested, the effectiveness of that approach becomes highly questionable. Less expensive methods based on planning the clinic space, use of inexpensive sound treatments, and selecting an appropriate earphone can be effective in almost any space that would be used for hearing testing.

Related Organizations
Keywords

Audiometry, Facility Design and Construction, Health Facility Environment, Humans, Reproducibility of Results, Noise

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    26
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Top 10%
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
26
Top 10%
Top 10%
Top 10%
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!