Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Journal of Electroni...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Journal of Electronics Electromedical Engineering and Medical Informatics
Article . 2022 . Peer-reviewed
License: CC BY SA
Data sources: Crossref
versions View all 1 versions
addClaim

Planning a Protection Coordination System Against Over Current Relays and Ground Fault Relays Using the NN Method

Authors: null Siti Zaibah; Anggara Trisna Nugraha; Fortunaviaza Habib Ainudin;

Planning a Protection Coordination System Against Over Current Relays and Ground Fault Relays Using the NN Method

Abstract

PT PAMA PERSADA is one of the power plants located in Kalimantan, Barunang which has 2 feeders. In one of the feeders, protection coordination often occurs. These disturbances can hamper the performance of the company PT PAMA PERSADA. This turned out to be a disturbance in the coordination of protection types of overcurrent relays and ground fault relays. Where in the end it takes an evaluation analysis of the relay setting coordination using the Electrical Transient Analysis Program (ETAP) 19.0.1 software on the electrical system. The disturbance that occurs is in feeder 2 which is divided into KM30 and Parilahung substations. This disturbance occurs because the relay coordination trips work simultaneously. From the results of the ETAP simulation, the power value is 4.164 KW, the reactive power is 780.3 KVAR, the apparent power is 4.237 KVA, and the cos phi value used is 0.9. Meanwhile, the protection coordination setting meets the IEEE 60255 standard with a grading time of 0.2 – 0.6 second. After being successfully simulated with the Electrical Transient Analysis Program (ETAP) 19.0.1 software, it was continued with the Matlab software which was used as an optimization of the relay settings and the use of the working effect of the NN (Neural Network) method. In accordance with the MSE (Main Square Error) value it reached 0.33452.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
gold