Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Journal of Electroni...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Journal of Electronics, Electromedical Engineering, and Medical Informatics
Article . 2022 . Peer-reviewed
License: CC BY SA
Data sources: Crossref
versions View all 1 versions
addClaim

Mechanical Fetal Simulator for Fetal Doppler Testing

Authors: Arum Triwerdani; Syaifudin Syaifudin; Bedjo Utomo; Abdul Basit;

Mechanical Fetal Simulator for Fetal Doppler Testing

Abstract

The continuous use of fetal Doppler allows for discrepancies in values ​​that lead to misdiagnoses in patients. This study aims to determine the effect of sound source distance on the fetal simulator with the measurement point. The contribution of this research is that the mechanical fetal heart system has 4 distances so that later it can be analyzed whether there is an influence of the location of the sound source on the accuracy of measurements using a fetal simulator. To get the desired distance, a solenoid is used which ends with a pipe of 2 cm, 5 cm, 10 cm, and 50 cm respectively. The solenoid used in the fetal simulator functions as a producer of the fetal heart. There is a rotary switch that functions for solenoid selection, namely 2 cm, 5 cm, 10 cm and 50 cm solenoids. Data collection was carried out on each solenoid and by placing the Doppler probe perpendicular and tilted. On the solenoid with a distance of 50 cm all measurement results exceed the allowable tolerance limit. The results showed that the BPM value of the two Doppler brands did not have a significant difference in value. When measuring fetal Doppler, the largest error value was 2.67%. The results of this study can be used as a reference when conducting an examination

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    0
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
0
Average
Average
Average
gold