Abstract In reliability test some chips suffered functional failure. Through a series of failure analysis experiments, the root cause was determined to be a silicon dislocation across LDD (Lightly Doped Drain) area causing p-n junction leakage. However, those failed samples all passed both CP (Chip Probe) and FT (Final Test) monitor. Therefore, it is reasonable to suspect that DVS (dynamic voltage stress) may enhance minor dislocations already existing before CP and FT. To prove this hypothesis, an experiment was designed to find the relationship between DVS and the depth of dislocation in silicon substrate. In conclusion, DVS could enhance dislocation across LDD area, which may induce reliability failure. Moreover, reliability concerns on this finding will be discussed in this paper.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |