doi: 10.3133/ofr83702
A preliminary study of the feasibility of using geophysical exploration methods to locate abandoned wells containing steel casing indicated that magnetic methods promise to be effective and that some electrical techniques might be useful as auxiliary methods. Ground magnetic measurements made in the vicinity of several known cased wells yielded total field anomalies with peak values ranging from about 1,500 to 6,000 gammas. The anomalies measured on the ground are very narrow and, considering noise due to other cultural and geologic sources, a line spacing on the order of 50 feet (15.2m) would be necessary to locate all casings in the test area.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 12 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |