
pmid: 22338952
Background: Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw following operative treatment of unstable ankle fractures. Methods: This was a retrospective study with consecutive cases in a Level-2 Trauma center. All patients with routine removal of a syndesmotic screw, following the treatment of an unstable ankle fracture, between January 1, 2004 and November 30, 2010 were included. Complications recorded were: 1) minor or major wound infection following removal of the syndesmotic screw, 2) recurrent syndesmotic diastasis, and 3) unnecessary removal of a broken screw, not recognized during preoperative planning prior to surgery. Results: A total of 76 patients were included. A wound infection occurred in 9.2% (N=7) of which 2.6% (N=2) were deep infections requiring reoperation. Recurrent syndesmotic diastasis was found in 6.6% (N=5) of patients, and in 6.6% (N=5) screws were broken at the time of implant removal. In the group with recurrent diastasis the screws were removed significantly earlier compared with the group without recurrent diastasis (Mann- Whitney U-test; p= 0.011) and the group with screw breakage had their screws significantly longer in place compared with the group without breakage ( p = 0.038). Conclusion: A total of 22.4% complications occurred upon routine removal of the syndesmotic screw. Removal might therefore be considered only in selected cases with complaints, after a minimum of eight to twelve weeks and using antibiotic prophylaxis during removal. Level of Evidence: IV, Retrospective Case Study
Adult, Male, Adolescent, Bone Screws, Middle Aged, Fracture Fixation, Internal, Fractures, Bone, Young Adult, EMC MUSC-01-47-01, Multivariate Analysis, Humans, Female, Ankle Injuries, Device Removal, Aged, Retrospective Studies
Adult, Male, Adolescent, Bone Screws, Middle Aged, Fracture Fixation, Internal, Fractures, Bone, Young Adult, EMC MUSC-01-47-01, Multivariate Analysis, Humans, Female, Ankle Injuries, Device Removal, Aged, Retrospective Studies
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 139 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 1% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 10% |
