pmid: 4669925
Auditory thresholds were determined by evoked response audiometry (ERA) and by routine clinical audiometry at two frequencies (500 and 2 000 Hz) for 50 adult patients by five audiologists. The differences between ERA results and routine audiometric results in this study suggest caution in the clinical use of data obtained by ERA.
Acoustic Stimulation, Audiometry, Air, Humans, Auditory Threshold, Evoked Potentials
Acoustic Stimulation, Audiometry, Air, Humans, Auditory Threshold, Evoked Potentials
citations This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 13 | |
popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |