Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ Journal of Orthopaed...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
Journal of Orthopaedic and Sports Physical Therapy
Article . 1999 . Peer-reviewed
Data sources: Crossref
versions View all 2 versions
addClaim

This Research product is the result of merged Research products in OpenAIRE.

You have already added 0 works in your ORCID record related to the merged Research product.

Reproducibility of Lumbar Spine Range of Motion Measurements Using the Back Range of Motion Device

Authors: Timothy J Madson; James W. Youdas; Vera J. Suman;

Reproducibility of Lumbar Spine Range of Motion Measurements Using the Back Range of Motion Device

Abstract

Single-group repeated measures for single rater reliability.To describe the intratester reliability for measurements of active lumbar spine mobility and pelvic inclination during standing obtained with the back range-of-motion (BROM) device.The BROM device has often been used to quantify lumbar spine active range of motion. No studies have reported the reliability of the BROM device in a clinical setting.One examiner measured all 3 planes of lumbar range of motion in 40 nonimpaired subjects. For each plane of motion, 2 BROM device measurements were made. Intraclass correlation coefficients were calculated to express the intratester reliability for each plane of motion measured.Intraclass correlation coefficients were in the range of 0.67 to 0.94 for lumbar measurements with the BROM device.Intratester reliability was fair to poor for sagittal plane measurements and pelvic inclination. Measurements obtained by the same examiner for lumbar lateral flexion and rotation with the BROM device, however, were reliable.

Related Organizations
Keywords

Adult, Male, Observer Variation, Reference Values, Lumbosacral Region, Humans, Female, Equipment Design, Range of Motion, Articular, Low Back Pain, Physical Therapy Modalities

  • BIP!
    Impact byBIP!
    citations
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    27
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Top 10%
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Top 10%
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
citations
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
27
Top 10%
Top 10%
Average
bronze