Potential weight efficiency for bead-stiffened panels has been demonstrated through fabrication and testing. Theoretically optimum design concepts were identified, and small specimens were tested under combined compression, shear, and bending to determine local buckling failure loads and to verify theory. Large optimized panels were then designed and tested under combined loads. Correlation of test data for large circular tubular panels with theory was conservative and consistent, and indicated reliable and acceptable design theory. Tests of fluted tubular panels indicated general instability failures at loads far below the design values due to nonlinear distortions. Further study of the fluted tubular configuration will be required if its potential weight efficiency is to be attained.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 2 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |