doi: 10.24084/repqj18.340
This paper presents the modelling, simulation and comparative study between switched reluctance generator 8x6 and switched reluctance generator 12x8. During work, the structural properties of the rotor and stator laminates of these machines are exposed. This information was used to perform mathematical modelling for both topologies. Based on this modelling, a computer simulation model was developed in the Simulink/Matlab® environment where several tests were carried out. To ensure comparability between machines, the output power in both topologies was set to 735,5 VA. After analyzing the results obtained during the simulations, it was found that the topology of the switched reluctance generator 8x6 is more efficient than 12x8
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 1 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |