doi: 10.2172/6593259
An axial array of B/sub z/ probes is used to monitor the formation and initial motion of the x-point of the separatrix in a field-reversed configuration. The x-point is observed to form near the outside edge of the main coil at approximately 3.0 ..mu..s after main field initiation and then move rapidly toward the center of the coil.
Theta Pinch, Magnetic Field Configurations, Probes 700202* -- Fusion Power Plant Technology-- Magnet Coils & Fields, Monitoring, Magnetic Probes, Reverse-Field Pinch, Pinch Effect, Magnetic Field Reversal, 70 Plasma Physics And Fusion Technology
Theta Pinch, Magnetic Field Configurations, Probes 700202* -- Fusion Power Plant Technology-- Magnet Coils & Fields, Monitoring, Magnetic Probes, Reverse-Field Pinch, Pinch Effect, Magnetic Field Reversal, 70 Plasma Physics And Fusion Technology