doi: 10.2172/654175
This report presents the assessment of the RELAP5/Mod3 (5m5 version) code subcooled boiling process model which is based on a variety of experiments. The accuracy of the model is confirmed for a wide range of regime parameters for the case of uniform heating along the channel. The condensation rate is rather underpredicted, which may lead to considerable errors in void fraction behavior prediction in subcooled boiling regimes for nonuniformly or unheated channels.
Computers, Mathematical Models, 21 Nuclear Power Reactors And Associated Plants, Pwr Type Reactors, 22 Nuclear Reactor Technology, Two-Phase Flow, Bwr Type Reactors, Subcooled Boiling, 99 Mathematics, Reactor Accidents, Management, Miscellaneous, Void Fraction, Evaluation, Law, Information Science, R Codes
Computers, Mathematical Models, 21 Nuclear Power Reactors And Associated Plants, Pwr Type Reactors, 22 Nuclear Reactor Technology, Two-Phase Flow, Bwr Type Reactors, Subcooled Boiling, 99 Mathematics, Reactor Accidents, Management, Miscellaneous, Void Fraction, Evaluation, Law, Information Science, R Codes
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 9 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |