doi: 10.21236/ada042114
Abstract : Micro Measurements FM Fatigue Sensors were installed on A-37 aircraft at three CONUS bases to determine the longevity and suitability of this device for field installation. A similar installation on an A-37B full scale fatigue test provided base line data for relative severity comparisons of accumulated fatigue. The sensor is shown to be practical for field installation and this report recommends field installations designed for more advanced data analysis methods. (Author)
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 0 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |