
doi: 10.2106/jbjs.m.01591
pmid: 25410511
The presence of leukocyte esterase in the synovial fluid has recently been proposed as a marker for periprosthetic joint infection. However, the sensitivity and specificity of leukocyte esterase has not been determined when matched for the current, most inclusive Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection.The presence of leukocyte esterase was prospectively evaluated in synovial joint aspirates from hips and knees from May 2009 to May 2013. The cohort consisted of 189 hip and knee aspirations (fifty-two positive and 137 negative for infection). If the aspirate was bloody, a centrifuge was used to precipitate red blood cells and obtain clear synovial fluid. A standard chemical test strip (graded as negative, trace, +, or ++) was used to detect the presence of leukocyte esterase. The sensitivity, specificity, positive predictive value, and negative predictive value of the leukocyte esterase strip test were calculated using ++ and ++/+ as two positive strip result scenarios.Synovial fluid was obtained from 221 joints that underwent revision total hip or total knee arthroplasty for either mechanical failure or periprosthetic infection. Due to the lack of adequate criteria for MSIS criteria classification, thirty-two joints were excluded. The leukocyte esterase test with a threshold of +/++ had a sensitivity, specificity, positive predictive value, and negative predictive value of 79.2% (95% confidence interval [CI], 65.9% to 89.2%), 80.8% (95% CI, 73.3% to 87.1%), 61.8% (95% CI, 49.2% to 73.3%), and 90.1% (95% CI, 84.3% to 95.4%), respectively. Using the ++ as a positive leukocyte esterase result, the sensitivity, specificity, positive predictive value, and negative predictive value were 66.0% (95% CI, 51.7% to 78.5%), 97.1% (95% CI, 92.6% to 99.2%), 89.7% (95% CI, 75.8% to 97.1%), and 88.0% (95% CI, 81.7% to 92.7%), respectively.When matched to the current MSIS criteria, the leukocyte esterase strip test yielded a high specificity, positive predictive value, negative predictive value, and moderate sensitivity. These results demonstrate that leukocyte esterase is an accurate, effective marker of periprosthetic joint infection as defined by the MSIS criteria. The leukocyte esterase strip test is a valuable tool that can be used in conjunction with the current battery of diagnostic tests available.
Male, coagulase negative Staphylococcus, Streptococcus group G, leukocyte esterase strip test, synovial fluid, Synovial Fluid, Enterococcus faecalis, Prospective Studies, total knee replacement, Aged, 80 and over, periprosthetic joint infection, predictive value, adult, Actinomyces israelii, Middle Aged, cohort analysis, aged, test strip, female, diagnostic test, diagnostic accuracy, Female, Knee Prosthesis, Corynebacterium jeikeium, prospective study, Adult, Staphylococcus aureus, Prosthesis-Related Infections, 610, Sensitivity and Specificity, Decision Support Techniques, male, Predictive Value of Tests, Humans, diagnostic test accuracy study, human, Gram-Positive Bacterial Infections, joint aspiration, Aged, total hip prosthesis, major clinical study, Orthopedics, sensitivity and specificity, erythrocyte, Hip Prosthesis, Carboxylic Ester Hydrolases, Biomarkers
Male, coagulase negative Staphylococcus, Streptococcus group G, leukocyte esterase strip test, synovial fluid, Synovial Fluid, Enterococcus faecalis, Prospective Studies, total knee replacement, Aged, 80 and over, periprosthetic joint infection, predictive value, adult, Actinomyces israelii, Middle Aged, cohort analysis, aged, test strip, female, diagnostic test, diagnostic accuracy, Female, Knee Prosthesis, Corynebacterium jeikeium, prospective study, Adult, Staphylococcus aureus, Prosthesis-Related Infections, 610, Sensitivity and Specificity, Decision Support Techniques, male, Predictive Value of Tests, Humans, diagnostic test accuracy study, human, Gram-Positive Bacterial Infections, joint aspiration, Aged, total hip prosthesis, major clinical study, Orthopedics, sensitivity and specificity, erythrocyte, Hip Prosthesis, Carboxylic Ester Hydrolases, Biomarkers
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 101 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Top 1% | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Top 10% | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Top 1% |
