Powered by OpenAIRE graph
Found an issue? Give us feedback
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/ edoc-Server. Open-Ac...arrow_drop_down
image/svg+xml art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos Open Access logo, converted into svg, designed by PLoS. This version with transparent background. http://commons.wikimedia.org/wiki/File:Open_Access_logo_PLoS_white.svg art designer at PLoS, modified by Wikipedia users Nina, Beao, JakobVoss, and AnonMoos http://www.plos.org/
versions View all 3 versions
addClaim

Automated Turbidimetry of Serum Lipoprotein(a)

Authors: Borque, L.; Maside, C.; Iglesias, A.;

Automated Turbidimetry of Serum Lipoprotein(a)

Abstract

We describe a simple iminunoturbidimetric method for quantifying lipoprotein(a) in serum based on latex-enhanced particle agglutination technology. Carboxylated latex particles (diameter 240 nm) covalently coated with F(ab')2 fragments of anti-lipoprotein(a) antibodies are incubated with the sample for 5 min at 37°C, and the resulting agglutination is quantified by measuring the change of turbidity produced at 700 nm. The assay is rapid, precise and fully automated on the Hitachi 911 analyser. The assay range is about 0.03—0.9 g/l. Average analytical recovery was 97.8%. Precision (CV) ranged from 1.9 to 3.1% at different lipoprotein(a) values. There was no interference from bilirubin, Intfalipid®, haemoglobin, plasminogen or apolipoprotein B. Comparisons with a latex nephelometric assay carried out on the Behring nephelometer analyser, and with three commercially available methods, a radioimmunoassay and two ELISA assays, gave good correlations (r > 0.95), although a large among-method variation in lipoprotein(a) values was found. We conclude that the proposed latex turbidimetric immunoassay method is suitable for routine use in clinical laboratories.

Peer Reviewed

Country
Germany
Keywords

ddc:540, Radioimmunoassay, Reproducibility of Results, Bilirubin, Enzyme-Linked Immunosorbent Assay, Plasminogen, Sensitivity and Specificity, Hemoglobins, 540 Chemie und zugeordnete Wissenschaften, Nephelometry and Turbidimetry, 540 Chemie, Calibration, Humans, Latex Fixation Tests, Apolipoproteins B, Lipoprotein(a)

  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    9
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
    OpenAIRE UsageCounts
    Usage byUsageCounts
    visibility views 88
    download downloads 83
  • 88
    views
    83
    downloads
    Powered byOpenAIRE UsageCounts
Powered by OpenAIRE graph
Found an issue? Give us feedback
visibility
download
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
views
OpenAIRE UsageCountsViews provided by UsageCounts
downloads
OpenAIRE UsageCountsDownloads provided by UsageCounts
9
Average
Average
Average
88
83
Green