Powered by OpenAIRE graph
Found an issue? Give us feedback
addClaim

An investigation on thermal necrosis during bone drilling

Authors: Gurmeet Singh; Aman Gahi; Vivek Jain; Dheeraj Gupta;

An investigation on thermal necrosis during bone drilling

Abstract

Drilling through bone is an old and effective method to get rapid cure from bone injury. During orthopaedic surgery we must need to fix the bones at their appropriate position so that it can rehabilitate at its natural position. Bone needs to be fixed with implants and screws for this overall curing process and drilling through bone is a necessary action for fulfilling the objective. For successive drilling through the bones a mechanical drilling system is used. Drilling mechanism for bone drilling is same as the mechanical drilling so heat is produced during bone drilling and affected the surroundings. The main challenge for bone drilling is to maintain the temperature below the threshold limit, which is 47°C in case of human bone. Exploitation of bone to above 47°C can cause osteonecrosis. Temperature produced during drilling depends upon the parameters selected for the drilling. So to maintain low temperature these parameters needs to be studied and needs to be controlled during drilling. This study mainly focuses on the effect of parameters on rise in temperature during bone drilling.

Related Organizations
  • BIP!
    Impact byBIP!
    selected citations
    These citations are derived from selected sources.
    This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    3
    popularity
    This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
    Average
    influence
    This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
    Average
    impulse
    This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
    Average
Powered by OpenAIRE graph
Found an issue? Give us feedback
selected citations
These citations are derived from selected sources.
This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Citations provided by BIP!
popularity
This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network.
BIP!Popularity provided by BIP!
influence
This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically).
BIP!Influence provided by BIP!
impulse
This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network.
BIP!Impulse provided by BIP!
3
Average
Average
Average
Upload OA version
Are you the author of this publication? Upload your Open Access version to Zenodo!
It’s fast and easy, just two clicks!