doi: 10.14359/5629
Twelve reinforced concrete deck panels were tested to study the potential of glass fiber reinforced polymer (GFRP) rebars as a replacement for epoxy coated steel (ECS) rebars in concrete bridge decks. Span lengths during testing were 2130 mm and 2740 mm. Three reinforcing schemes were evaluated in the study: an ECS reinforcing scheme, a GFRP reinforcing scheme, and a Hybrid reinforcing scheme with a top reinforcing mat of GFRP rebars and a bottom reinforcing mat of ECS rebars. A shear diagonal tension, failure mode was observed in the testing of the deck panel specimens with GFRP tensile reinforcement. Based on the test results, two equations for predicting shear capacity of GFRP reinforced concrete sections are presented.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |