Seven T-beams, post-tensioned with straight tendons, were tested to failure to investigate the effect of concrete strength, shear reinforcement, and shear span on the failure mode of externally prestressed beams. Each beam was fabricated with a deviator at the midspan and tested under simply supported conditions. The beams were each subjected to equal concentrated loads at third-points, except for one, which was subjected to a concentrated load at the midspan. Test results indicated that decreasing the concrete strength or the amount of shear reinforcement leads to shear-type failure of the beam. When an appropriate concrete strength and amount of shear reinforcement are provided, flexural-type failure prevails even for shear span to effective depth ratio of as low as 2.5. Analytical considerations based on a strut-and-tie model that was proposed earlier showed good predictions of the ultimate strength and failure mode of the test beams.
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |