doi: 10.14359/51686817
Punching shear design criteria of corner slab-column connections in ACI 318-11 are controversial. This paper presents some of the relevant issues using design examples. Two approximately full-scaled corner slab-column subassemblages were tested under combined gravity load and lateral displacement reversals. Each specimen consists of a 120 × 120 × 8 in. (3048 × 3048 × 203 mm) slab and an approximately 140 in. (3556 mm) high column with a 16 in. (406 mm) square cross section. A total of 36 experimental results are collected to evaluate design criteria of corner slabcolumn connections in ACI 318-11. Experimental results showed that both punching shear strength and deformation capacities in ACI 318-11 should be reduced for corner slab-column connections.
Flat-plate, Capacity, Demand, Punching shear, Deformation
Flat-plate, Capacity, Demand, Punching shear, Deformation
| selected citations These citations are derived from selected sources. This is an alternative to the "Influence" indicator, which also reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | 3 | |
| popularity This indicator reflects the "current" impact/attention (the "hype") of an article in the research community at large, based on the underlying citation network. | Average | |
| influence This indicator reflects the overall/total impact of an article in the research community at large, based on the underlying citation network (diachronically). | Average | |
| impulse This indicator reflects the initial momentum of an article directly after its publication, based on the underlying citation network. | Average |